PerkinElmer

搜索 Results for 'DSC'

产品与服务 (51)
Filters:

幸运8平台彩票 Filters :

显示结果
产品类型
  • Accessories (18)
  • Consumables (29)
  • Instruments (4)
材料
  • Aluminum (13)
  • Gold (1)
  • Plastic Body (1)
  • Platinum (3)
  • Stainless Steel (2)
  • Titanium (1)
Maximum Temperature (Celcius)
  • Over 100 (4)
型号兼容
  • Diamond DSC (2)
  • Diamond DSC, DSC 8000, DSC 8500 (1)
  • Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, Jade DSC (3)
  • Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, Jade DSC, DSC -4 RS (2)
  • Diamond DSC, Pyris 1 DSC, DSC 7, DSC 8000, DSC 8500, DSC -2 (1)
  • Diamond DSC, Pyris DSC, DSC 7, DSC 6, Pyris 6 DSC, Jade DSC (1)
  • DSC -4 RS (1)
  • DSC 4000, DSC 6000 (1)
  • DSC 4000, DSC 6000, DSC 8000, DSC 8500, Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyris 6 DSC, Jade DSC (4)
  • DSC 7 RS (1)
  • DSC 8000, DSC 8500, Diamond DSC, Pyris 1 DSC (1)
  • Pyris 1 Autosampler (1)
  • Pyris 1 DSC (1)
  • Pyris 1 DSC, Diamond DSC, DSC 8000, DSC 8500 (2)
  • Pyris 1, DSC 7 RS, DSC -4 RS (2)
  • Pyris 1, DSC 7 RS, DSC -4 RS, Diamond DSC, DSC 8000, DSC 8500 (1)
产品组
  • Calibration (TEA) (4)
  • Connectors (1)
  • Cooling System (8)
  • Cover Kit (1)
  • Covers (3)
  • FIAS/FIMS Cell Replacement Parts (1)
  • GC Compressor (2)
  • Guard Rings (1)
  • O-Rings (1)
  • Pan Crimper (1)
  • Pan Crimpers (1)
  • Sample Holder Cover (1)
  • Sample Holder Covers (1)
  • Sample Loading Tool (1)
  • Sample Pans (15)
  • Sample Pans, Covers, O-Rings (1)
  • Starter Kit (1)
技术
  • Thermal Analysis (4)
技术类型
  • DSC (23)
  • Thermal Analysis (4)
技术
  • Thermal Analysis (4)
体积容量
  • 10 µL (1)
  • 30 µL (2)
  • 40 µL (3)
  • 50 µL (3)
  • 60 µL (1)
标准型
  • Reference Materials (4)

1-12 的 51 产品与服务

幸运8平台彩票

  • DSC 4000 系统, 100-240V/50-60Hz

    DSC4000型差示扫描量热仪采用单炉体设计,结构紧凑,性能十分优异。应用范围广泛,覆盖了从日常教学科研、新材料表征药物研发以及市场常规检测等诸多领域。可提供可靠的性能、优异的数据重现性以及简便的操作方法。此外,其包覆式热电偶设计可耐受氧气和化学物质的侵蚀,服役寿命长。
  • LAB SYS-DSC 8500

    DSC8500拥有第二代HyperDSC技术、双炉体设计和更佳的测试能力,其准确度和灵敏度胜过目前任何一款DSC。
  • DSC 8000

    DSC 8000特有的双炉体技术,直接测量两个独立炉体之间热流变化,可在全程温度范围得到非常准确的能量数据,从而满足您在科研方面的高级需求。
  • DSC6000

    DSC 6000

    DSC6000型差示扫描量热分析仪采用单炉体设计,除了具备DSC4000型仪器的所有性能优势以外,还可提供给您更多的特性设计。标配的温度调制技术(MT-DSC)简化了数据分析过程,适用于新产品的研发以及疑难问题解决等应用领域。
  • PerkinElmer

    Aluminum Pan Starter Kit

    Includes 400 aluminum pans and 2000 covers.
  • PerkinElmer

    Guard Rings for Diamond DSC, Pkg. 2

    Includes 2 guard rings. These guard rings are for use with the Diamond DSC and they protect the sample holder cavity by preventing sample from falling into the cavity causing damage to the sample and reference furnaces.
  • PerkinElmer

    Aluminum Pan Starter Kit

    The Aluminum Pan Starter Kit includes 50 of each type of aluminum pan and 350 covers. This starter kit is for use with the Pyris 1 Autosampler, DSC 7 RS and DSC -4 RS.
  • HyperDSC Aluminum Sample Pans, Pkg. 100

    Includes 100 ultra-light sample pans that have a 6 mm width and 3.75 mm height. These pans do not require a sealing tool and have an operating range of -170 ° to 600 °C, a volume of 50 µL, and an ambient maximum pressure.
  • PerkinElmer

    Aluminum Covers - Pierced 0.05 mm Holes

    Includes 400 covers. These covers have an operating range of -170° to 600 °C and are pierced with a 0.05 mm hole. For use with (B0169319), (B0169320), and (B0169321).
  • Indium Calibration Reference Material, Transition Point: 156.60°C

    PerkinElmer reference materials are 99.999% pure. DSC requires elements of this purity so that the instrument can be accurately calibrated. Depend on PerkinElmer for quality calibration reference materials.
  • PerkinElmer

    Tin Calibration Reference Material, Transition Point: 231.88°C

    PerkinElmer reference materials are 99.999% pure. DSC requires elements of this purity so that the instrument can be accurately calibrated. Depend on PerkinElmer for quality calibration reference materials.
  • PerkinElmer

    Lead Calibration Reference Material, Transition Point: 327.47°C

    PerkinElmer reference materials are 99.999% pure. DSC requires elements of this purity so that the instrument can be accurately calibrated. Depend on PerkinElmer for quality calibration reference materials.
  • Jump to:
Business Insights (6)
Filters:

1-6 的 6 Business Insights

  • 应用文献

    High Resolution Characterization of Pharmaceutical Polymorphs Using Power Compensation DSC

    Many pharmaceutical materials exhibit polymorphism, which means that, depending upon the given processing conditions, the crystalline form may exist in two or more states. The crystalline states or forms exhibit different levels of thermodynamic stabilities and an unstable form can melt at a temperature significantly less than the melting point of the thermodynamically stable form. Depending upon the conditions used to generate the crystalline form(s), the drug may exhibit one or more unstable, polymorphic crystalline states.

  • 应用文献

    Study Rigid Amorphous Fraction in Polymer Nano-Composites by StepScan and HyperDSC

    幸运8平台彩票Heat capacity measurement has been performed in order to detect a possible second Tg on nanocomposites of polymethyl methacrylate (PMMA) with silicon oxide nanoparticles of different shape. StepScan™ DSC was used for determination of precise heat capacity and HyperDSC® to prevent degradation and identify devitrification of the RAF at elevated temperatures.

  • 应用文献

    Improved HyperDSC Method to Determine Specific Heat Capacity of Nanocomposites and Probe for High-Temperature Devitrification

    Where ΔCp and ΔCp pure are the changes in specific heat at the glass transition temperature, Tg, for the composite, and for the unfilled polymer, respectively. This work suggests an alternative method for determining Cp that takes advantage of fast heating and cooling rates to obtain quantitative Cp in the upper temperature region without having to dwell in that high temperature region to establish an upper isothermal.

  • 应用文献

    Curing Determination of EVA for Solar Panel Application

    This study shows that DSC can be used to study the curing degree of the EVA resin by measuring the residual curing enthalpy. The data show that the residual curing enthalpy can be correlated to the curing time in a linear way. The DSC test is quick and easy.

  • 应用文献

    HyperDSC for High Throughput Formulation Development

    The concept of High-Throughput Design has gained more and more interest as a way to increase profitability and to decrease research costs. One technique that can increase the ability of a laboratory to evaluate formulations is HyperDSC™ or High Ramping Rate DSC. HyperDSC is the ability to quantitatively measure small samples at extreme heating and cooling rates, typically 100-500 °C/min.

  • 应用文献

    Pharmaceutical Compounds are Analyzed in Half the Time by Simultaneous TGA-DSC

    幸运8平台彩票In the “Early Drug Discovery Phase” of pharmaceutical development when there is a minimum amount of synthesized drug candidate, quick thermal analysis using a small amount of sample is the norm. The sample amount could be less than 3 mg. Because of the rush to identify possible drug candidates, analytical answers must be given within the day. The STA 6000 with its sensitivity of 0.1 µg allows minimum sample material to obtain reproducible results in half the time.