Spotlight 400 FT-IR Imaging System | PerkinElmer

幸运8平台彩票

PerkinElmer
check quantity

Spotlight 400 红外成像系统

The Spotlight 400 FTIR Imaging System combines high sensitivity and rapid imaging with ease-of-use. The ability to image rapidly large sample areas at high spacial resolution (down to 10 microns) extends IR microscopy into new applications.

部件号 L1860116
立即购买

请输入有效的数量

幸运8平台彩票 请登录后再添加至收藏夹

幸运8平台彩票 购物车为空

项目已成功添加到购物车

详情 信息

  • Solid-state white light illumination
  • Fully-automated focus, stage movement and illumination
  • Duet detector design containing a single element MCT detector and a linear array MCT imaging detector
  • Can operate in mid-IR, near-IR or dual range to cover the full range of imaging applications in one instrument
  • Optional ATR imaging improves the spacial resolution by a factor of four, down to 3 microns at 1000 cm-1

FTIR Microscopy & Imaging Systems provides a full line of innovative IR Microscopy and Imaging Systems, software, sampling accessories and services to laboratories worldwide, improving product quality, productivity and analytical processes. We are the only instrument manufacturer to achieve the maximum spatial resolution across our entire product range. Our instruments feature optics designed specifically for infrared applications and, because minimal manual adjustment is required, ease-of-use is greatly increased.

  • Very high sensitivity providing high quality data down to the accepted diffraction limits
  • Rapid-scan IR imaging
  • 6.25µm, 25µm and 50µm pixel resolution to give flexibility in spacial resolution and imaging line
  • Can operate in mid-IR, near-IR or dual range to cover the full range of imaging applications in one instrument
  • Optional ATR imaging improves the spacial resolution by a factor of four, down to 3 microns at 1000 cm-1

幸运8平台彩票Key Applications

  • Product defect analysis
  • Impurity identification
  • Pharmaceutical table analysis and other component distribution studies
  • Forensics
  • Academic research
  • Biomaterial studies such as tissue, bone, teeth, leaves, etc.

规格

21 CFR Part 11兼容 Yes
深度 57.0 cm
Detector Type MCT
高度 47.0 cm
工作范围(-60to400) 5 – 40 °C
便携式 No
产品品牌名称 Spotlight
产品组 Instrument
保修 1 year
波长 7800-600 cm-1
波长范围 7,800 – 600 cm-1
重量 32.0 kg
宽度 34.0 cm

配置

Model Spotlight Detector Frontier Options Standard Features Optional Extras
Spotlight 400 – Frontier MIR MCT or DTGS
  • Standard MIR system with LiTaO3 detector
  • MIR system with temperature-stabilized DTGS detector
  • MIR system with CsI optics to enable the Frontier to sample over a spectral range of 7,800-250 cm-1
  • Spectrum 10
  • SpectrumIMAGE
  • MultiSearch
  • Motorized stage control unit
  • PC with Windows 7 and stage controller
  • AutoATR objective
  • ATR Imaging Accessory
  • NIR reflectance accessory
  • Microscopy polarizer kit
  • Heated stage accessory
  • Micro-sampling tool kit
Spotlight 400 – Frontier MIR/NIR MCT or DTGS
  • System with MIR and NIR DTGS detectors
  • System with MIR MCT and NIR DTGS detectors
Spotlight 400 – Frontier MIR/FIR MCT or DTGS
  • System with MIR and FIR DTGS detectors
资源,活动及更多信息
  • 所有

Story

链接

产品信息公告

产品手册

Infrared Imaging and Microscopy Systems

Introducing the PerkinElmer infrared imaging and microscopy systems family.

PDF 7 MB
PerkinElmer Frontier FT-IR, NIR and FIR Spectroscopy Brochure

幸运8平台彩票Choose the PerkinElmer Frontier™ range of near-, mid- and far-IR Fourier Transform spectrometers for superior spectroscopic performance in demanding applications. Powerful and adaptable, the Frontier meets all your current analysis needs and can be expanded as your research goals evolve. And with automated range switching, mid- near- or far-IR techniques are available at your fingertips. An exceptional signal-to-noise ratio and photometric performance assures optimal spectral performance to ensure best-in-class sensitivity. This configurable platform provides dependable, consistent and trouble-free operation through years of service.

PDF 12 MB
PerkinElmer Frontier and Spectrum Two FT-IR, NIR and FIR Spectroscopy Brochure

Frontier™ is PerkinElmer’s most powerful, adaptable IR solution yet, specially developed to offer superior performance in demanding applications.

PDF 2 MB
Spotlight™ 400 FT-IR and 400N FT-NIR Imaging Systems

With Spotlight 400 FT-IR and Spotlight 400N FT-NIR imaging systems, you experience unprecedented, uncompromising data quality and clear, complete, highly detailed results from all your samples. Spotlight FT-IR systems are purpose-built for a wide range of demanding imaging applications. So you’re able to switch between sampling modes – standard transmission, reflection, ATR imaging, and more – with ease, and your images can be collected.

PDF 7 MB
Spotlight™ 400 FT-IR and 400N FT-NIR Imaging Systems Brochure

幸运8平台彩票It’s not every day that a masterpiece is created. But how else does one describe a laboratory instrument that will dramatically improve the understanding of materials across an unprecedented range of industries. With the Spotlight™ 400, IR imaging just became faster, more efficient and more flexible than ever before. It is quite simply the most productive laboratory FT-IR imaging system in the world.

PDF 1 MB

产品说明

Spectrum Touch Software Product Note

幸运8平台彩票Using spectrum touch software and predefined operating procedures in IR and NIR analyses can help fulfill regulatory compliance requirements, decrease error rate and enable better communication of effective analysis with stakeholders

PDF 1 MB
TIBCO Spotfire Software for IR Instrumentation Product Note

Product note dscribes TIBCO Spotfire for IR Instrumentation software product from PerkinElmer that creates powerful visualizations to ensure the quality and consistency of your results-every time.

PDF 730 KB
Variable Temperature Stage Options for FT-IR Microscopes and Imaging Systems

There is an increased interest in the microscopic analysis of samples using FT-IR variable-temperature microscopy or imaging. Application areas include polymer studies, pharmaceutical and food analysis and geological measurements. PerkinElmer offers two options for variable temperature analyses – Linkam variable temperature sample cell and the hot stage accessory.

PDF 255 KB

合规认证证书

PDF 63 KB

应用文献

ATR FT-IR Imaging of Human Hair Cross-Section

幸运8平台彩票Human hair is typically 50-100 µ in diameter, previous transmission and ATR studies of its cross section1,2 reveal three major identifiable regions.

PDF 598 KB
ATR Imaging of Pharmaceutical Tablets

Technology improvements and increased use has established chemical imaging as a means of providing information on certain critical quality parameters that is not readily addressable using other techniques.

PDF 1 MB
Augmenting Standard Methods of Measuring Airborne PM2.5 Using IR Imaging

The use of IR imaging expands the measurement possibilities by giving information about the individual types of materials present in the collected particles. The information from the IR imaging experiment is not only qualitative (i.e. identification of the particulates), but can also be calibrated to give quantitative information on the components present. The IR imaging measurement will take only five minutes, whereas Ion Chromatography requires solvent extraction of the particulates and would take around 20-25 minutes per sample

PDF 1 MB
FT-IR Imaging Capabilities in Pharmaceutical and Biopharmaceutical Segments

幸运8平台彩票FT-IR Imaging has excellent potential in sample characterization within the Injectables segment of Pharma and Biopharma sector for impurity identification.

PDF 1 MB
FT-IR Imaging Dara from Sectioned Tomato Seed

幸运8平台彩票The following data was obtained from a sectioned of tomato seed and analyzed using the PerkinElmer spotlight FT-IR imaging system. The section was placed onto a Barium Fluoride window and the infrared data was obtained in transmission mode.

PDF 346 KB
FT-IR Imaging Study on Stoma of Limonium

There are many stomata (thousands per square centimeter) in the lower epidermis of plant leaves. Two crescent-shaped cells called guard cells, which are rich in chloroplasts, flank the stoma. Starch is produced in daytime by photosynthesis within the guard cells, not in adjacent epidermal cells.

PDF 610 KB
FT-IR Mircoscopic Analysis of Microplastics in Bottled Water

幸运8平台彩票Bottled water is marketed as being the clean and pure alternative to drinking tap water. However, there is increasing opposition to the use of single-use plastic bottles and the fact that they end up in the environment either as intact bottles, or as secondary microplastics when they do break down into smaller pieces and particles. A recent study also reports that microplastic particles have been detected in several brands of bottled drinking water. The effects on human health from microplastics are still to be determined, but the presence of microplastics, potentially containing priority organic pollutants (POPs), in food and beverages is a major concern. Infrared (IR) spectroscopy is the primary analytical technique for the identification of polymers and the use of IR microscopy allows for the detection and identification of microplastics down to particles of only a few microns in size. This application note describes the analysis of several different brands of bottled water using the PerkinElmer Spotlight 400 FT-IR Imaging system.

PDF 2 MB
IR Microscopy Used in Effort to Solve Mystery: Did Mallory Climb Everest in 1924?

幸运8平台彩票FT-IR Microscopy quickly provides a unique fingerprint of a complicated material made up of multiple constituents. Another advantage of this technique is that it requires little or no sample preparation and that it can generate spectra in a matter of a few minutes.

PDF 175 KB
Measurement of Counterfeit Pharmaceuticals Using the Spotlight Imaging System

The Spotlight FT-NIR Imaging System is ideally suited to the rapid identification of counterfeit drugs based on the distribution of ingredients.

PDF 1 MB
多层材料的ATR红外光谱成像分析

本报告叙述了高分子多层材料的ATR光谱成像测量方法,为多层材料样品的实际测量提供了一些操作建议。

PDF 3 MB

技术说明

Large Area ATR FT-IR Imaging Using the Spotlight FT-IR Imaging System

幸运8平台彩票ATR FT-IR imaging offers users easy spectroscopic access to “difficult” samples which are hard to image in transmission or reflection, or which have confusing depth structure.

PDF 702 KB
Spatial Resolution in ATR FT-IR Imaging: Measurement and Interpretation

ATR FT-IR imaging with germanium crystals offers the potential for acquiring infrared spectral images at up to four times higher spatial resolution than is possible using conventional reflectance or transmission imaging.

PDF 264 KB

指南

Material Characterization Instrument Guide

Guide describing all UV/Vis spectroscopy, FT-IR spectroscopy, thermal analysis, hyphenation technique solutions for material characterization.

PDF 7 MB

案例分析

Infrared Microscopy Provides More Accurate Kidney Stone Diagnosis

幸运8平台彩票A recent study has demonstrated that the accuracy of kidney stone diagnosis can be substantially improved by switching from conventional optical microscopy and contrast staining to infrared (IR) microscopy. There are over a dozen different types of kidney stone, and diagnosing the type is important because most effective treatment methods vary for each.

PDF 436 KB
Spotlight FT-IR Imaging System Helps Forensic Lab Win Triple Murder Conviction

Analyses using infrared microspectroscopy; performed by the Michigan State Police Forensic; Science Division (MSPFSD); Lansing Laboratory; helped to win a triple murder conviction by matching paint from one victim’s clothing to the murderer’s car.

PDF 306 KB

海报

Advanced Solutions for Polymers And Plastics Poster

Poster summarizing solutions of thermal analysis, molecular spectroscopy, chromatography and hyphenated techniques for polymers focused on providing more insight into product performance and process optimization that make easier

PDF 2 MB
Microplastics and their Alternatives for Intentional Use in Products Environmental Agency Austria Poster

This poster describes analytical application example of FT-IR microspectroscopy for microplastic analysis which are used as exfoliating microbeads in cosmetics and personal care products

PDF 1 MB
Tablet uniformity measurements using Near-IR Spectroscopy

幸运8平台彩票Among the FDA’s top reasons for product recall were problems with sub-potency and tablet dissolution. In addition, recent cases of cGMP violations have highlighted issues in tablet manufacturing. One area where industry is seeking to improve its processes is in the blending area.

PDF 308 KB

白皮书

日益令人担忧的水体微塑料

幸运8平台彩票该白皮书介绍了水体中微塑料带来的问题以及……