Spectrum Two | FT-IR Spectrometer | PerkinElmer

幸运8平台彩票

PerkinElmer
check quantity

Spectrum Two 红外光谱仪

Easy to use, powerful, compact and robust – Spectrum Two is the FT-IR spectrometer of choice for everyone, everywhere. With fully integrated, robust universal sampling for trouble-free measurements and portability options, Spectrum Two is ideal for use in both laboratory and remote testing environments. Ideally suited to everyday analysis, you can confidently perform fast, accurate IR analysis and assure the quality of your materials across a wide range of applications.

项目已成功添加到购物车

部件号
Detector Type
L160000A
[LiTaO3]
更多
L160000F
[DTGS]
更多
立即购买

幸运8平台彩票 请输入有效的数量

请登录后再添加至收藏夹

幸运8平台彩票 购物车为空

详情 信息

红外整装待发

Spectrum Two™ 是任何人,任何地方都能选择的一款红外光谱仪。非常适用于日常分析检测,您完全可以自信地去执行快速准确的红外分析以及广泛用于各类应用保证您材料的质量。开辟了新的操作简便性,Spectrum Two联合了极好的性能和极少的维护设计。

幸运8平台彩票Spectrum Two 的标准配置适用于广泛的应用,包括高性能的检测器、带样品插槽的标准样品仓和全面的Spectrum 10™,以及 Spectrum 10™的升级软件接口。另外,DTGS检测器的配置也可提供。

规格

21 CFR Part 11兼容 Yes
深度 30.0 cm
Detector Type LiTaO3
高度 21.0 cm
工作范围(-60to400) 5 - 45 °C
便携式 Yes
产品品牌名称 Spectrum Two
保修 1 year
波长 8
波长范围 8,300 – 350 cm-1
重量 13.0 kg
宽度 45.0 cm

配置

Detector Type Windows APV/AVI? Software Part Number
LiTaO3 KBr No Spectrum 10 L160000A
LiTaO3 KBr No Spectrum 10 ES L160000I
LiTaO3 KBr Yes Spectrum 10 L160000B
LiTaO3 KBr Yes Spectrum 10 ES L160000J
LiTaO3 ZnSe No Spectrum 10 L160000C
LiTaO3 ZnSe No Spectrum 10 ES L160000K
LiTaO3 ZnSe Yes Spectrum 10 L160000D
LiTaO3 ZnSe Yes Spectrum 10 ES L160000L
资源,活动及更多信息
  • 所有

应用文献

链接

Story

链接

链接

产品信息公告

产品手册

PerkinElmer Frontier FT-IR, NIR and FIR Spectroscopy Brochure

Choose the PerkinElmer Frontier™ range of near-, mid- and far-IR Fourier Transform spectrometers for superior spectroscopic performance in demanding applications. Powerful and adaptable, the Frontier meets all your current analysis needs and can be expanded as your research goals evolve. And with automated range switching, mid- near- or far-IR techniques are available at your fingertips. An exceptional signal-to-noise ratio and photometric performance assures optimal spectral performance to ensure best-in-class sensitivity. This configurable platform provides dependable, consistent and trouble-free operation through years of service.

PDF 12 MB
PerkinElmer Frontier and Spectrum Two FT-IR, NIR and FIR Spectroscopy Brochure

Frontier™ is PerkinElmer’s most powerful, adaptable IR solution yet, specially developed to offer superior performance in demanding applications.

PDF 2 MB
Spectrum Two FT-IR Spectroscopy Brochure

幸运8平台彩票This brochure describes easy to use, powerful, compact and robust – Spectrum Two™ IR spectrometer suited to a wide range of applications.

PDF 8 MB
Spotlight 150i 200i FT-IR Microscope Systems Brochure

This brochure describes the Spotlight 150i and Spotligh 200i FT-IR Microscope System technology.

PDF 1 MB
Spotlight™ 400 FT-IR and 400N FT-NIR Imaging Systems Brochure

幸运8平台彩票It’s not every day that a masterpiece is created. But how else does one describe a laboratory instrument that will dramatically improve the understanding of materials across an unprecedented range of industries. With the Spotlight™ 400, IR imaging just became faster, more efficient and more flexible than ever before. It is quite simply the most productive laboratory FT-IR imaging system in the world.

PDF 1 MB

产品说明

Polymer Recycling Pack

Product Note, Thermal Analysis, Polymenr Recycling Pack, Polyethylene Terephthalate, PET, polyethylene, PE, Polycarbonate, PC, Polystyrene, PS, Spectrum Two, Fourier Transform Infrared, FT-IR, Universal Attenuated Total Relectance, UATR, High Density Polyethylene, HDPE, Low Density Polyethylene LDPE, Differential Scanning Calorimetry, DSC, Thermogravimetric Analysis, TGA, Thermal Analysis

PDF 554 KB
Spectrum Quant Quantitative Analysis Software

Unleash the potential of your PerkinElmer FT-IR and NIR spectrometers with Spectrum® Quant software. Designed for novice and advanced spectroscopists who need to integrate accurate quantitative analysis into their IR or NIR analysis.

PDF 2 MB
Spectrum Touch Software Product Note

Using spectrum touch software and predefined operating procedures in IR and NIR analyses can help fulfill regulatory compliance requirements, decrease error rate and enable better communication of effective analysis with stakeholders

PDF 1 MB
TIBCO Spotfire Software for IR Instrumentation Product Note

幸运8平台彩票Product note dscribes TIBCO Spotfire for IR Instrumentation software product from PerkinElmer that creates powerful visualizations to ensure the quality and consistency of your results-every time.

PDF 730 KB

合规认证证书

应用文献

PDF 2 MB
Advantages of Adulterant Screen for Detection of Olive Oil Adulteration by Attenuated Total Reflectance (ATR) FT-IR

Application Note, Adulterant Screen, Detection Olive Oil, Attenuated Total Reflectance, ATR, FT-IR, Infrared, Spectrum 2, Spectrum Two, SIMCA, PCA, PLS, Spectrum Touch

PDF 2 MB
Analysis of Bioethanol Impurities with the Spectrum Two FT-IR Spectrometer

幸运8平台彩票The intensifying global emphasis on developing sustainable fuel supplies has led to increasing use of fuels derived from biological sources. In this note we show that the Spectrum Two™ FT-IR spectrometer (Figure 1) can be used to develop a quantitative method with sufficient sensitivity to meet the required detection limits for methanol, water, C3–C5 alcohols and gasoline denaturant, while requiring less than two minutes of analysis time per sample.

PDF 814 KB
Biodiesel Concentration Measurements Using Attenuated Total Reflectance (ATR)

Biodiesel fuels are often blended compositions of diesel fuel and esterified soybean oils, rapeseed oils, or other potential vegetable oils as well as fats. The physical and combustion properties of these biofuels have allowed them to achieve similar performance to diesel fuel. However, there are several characteristics that are of concern. These differences, especially the cetane reduction, require that adequate control of the biofuel concentration be implemented.

PDF 1 MB
Characterization of Textile Fibers Using the PerkinElmer Spectrum 100 with Universal ATR Polarization Accessory

幸运8平台彩票The ability to accurately characterize textile fibres is important in many fields, including textile conservation, forensic analysis and industrial production. Conventional methods such as microscopy and spectroscopy can be used to investigate the morphology and chemistry of a sample, but reveal little about its miscrostructure.

PDF 233 KB
Determination of Benzene in Gasoline by ASTM D6277 with Spectrum Two

IR spectroscopy is an ideal method for quantifying benzene at the concentration levels required, and there are several standard methods for this measurement, all of which utilize the distinctive C–H out-of-plane deformation band at around 673 cm-1. While this band is characteristic of benzene, toluene and xylenes have some weak absorption at this frequency that can interfere with the results if high concentrations are present.

PDF 451 KB
Determination of Hydrocarbons in Environmental Samples with Spectrum Two FT-IR

This note examines the Determination of Hydrocarbons in Environmental Samples with Spectrum Two FT-IR.

PDF 929 KB
Determination of Oil Content in Membranes Used in Compressed Air Sampling by Infrared Spectroscopy

This note describes the test method for the quantitative analysis of aerosol oil and liquid oil typically present in the air discharged from compressors and compressed air systems. The method is rapid, sensitive and cost effective and shows the FT-IR can be an effective tool for the monitoring of oil content. The methodology followed for the analysis by FT-IR is reported in Bureau of Indian Standard and we have also tested for its ruggedness, spike recovery, linearity and detection limits.

PDF 749 KB
Determination of Oil and Grease in Water with a Mid-Infrared Spectrometer

The concentration of dispersed oil and grease is an important parameter for water quality and safety. Oil and grease in water can cause surface films and shoreline deposits leading to environmental degradation, and can induce human health risks when discharge.

PDF 2 MB
Determining the Source Oil of Biodiesel with Infrared Spectroscopy

Infrared spectroscopy is particularly suitable for the identification of materials, even when the differences between the materials are subtle variations in complex mixtures. In this note we demonstrate that biodiesel from several common feedstocks can be distinguished on the basis of absorption bands arising from double bonds in the fatty acid chains.

PDF 176 KB
Diamond ATR and Calibration Transfer for Biodiesel-Blend Analysis by ASTM D7371

Biodiesel is seldom used neat (B100), typically being blended with fossil diesel at ratios from 5% v/v (B5) to 30% v/v (B30). Verifying the FAME content of diesel-fuel blends is an important aspect of quality control and auditing of blending and distribution operations. Because FAME has a strong infrared absorption at 1745 cm-1 due to the ester carbonyl group, infrared spectroscopy is an excellent technique for this analysis, and there are EN and ASTM® standard test methods describing the procedure

PDF 1 MB
Spectrum Two NFT-NIR 近红外光谱仪测定多元醇的羟值

该应用报告主要介绍利用近红外 (FT-NIR) 红外光谱仪测试多元醇样品,介绍样品整个测试过程,以及测试所使用的定量方法。

PDF 5 MB
Spectrum Two反式脂肪红外光谱分析包

幸运8平台彩票FT-IR Spectroscopy完全执行美国油类化学家学会(AOCS)制订的食用油类和脂肪中反式脂肪含量测试方法(AOCS Cd14e-09),可以在1%甚至更低含量水平上进行可靠测定。触摸屏控制、 工作流程驱动的软件界面内置了标准操作程序和清晰的说明,确保分析的可靠性。附带校正模板和快速启动标准操作程序。

PDF 775 KB
Spectrum Two测定甘油中掺杂物二甘醇

带有UATR附件的Spectrum Two仪器和Spectrum 10软件可以快速、准确的测试甘油原料。Compare算法可识别正确的原料。用Adulterant Screen 方法来有针对的筛选样品中怀疑有经济利益的掺杂物是非常有效的。这是一种简单、有效的方法来检测甘油原料中掺杂物二甘醇,其检出限为0.2%。Adulterant Screen 的另外一个优势是任何时候都允许添加新的掺杂物,并且能够与宏一起简单容易使用。在监管环境中Spectrum 10 ES提供所有所需的安全特性部署。

PDF 1 MB
Spectrum软件的掺杂物筛查

在产品的掺假检测中,从来没有像PerkinElmer中红外与近红外光谱仪中采用的Spectrum10软件掺杂物筛查功能这样容易。掺杂物筛查是基于强大的算法提供简单方法开发来保证对意外引入产品中材料的检测、识别与定量分析。

PDF 3 MB
The Advantages of Mid-IR Spectroscopy for Polymer Recycling

幸运8平台彩票Application Note, IR Spectroscopy, Polymer Recycling, Plastic Indentification Code, PIC, packaging materials, Spectrum Two, Diamond ATR, Mid-Infrared, Attenuated Total Reflectance, PET, HDPE, PVC, LDPE, PP, PS, Frontier, molecular spectroscopic

PDF 2 MB
中红外光谱仪在聚合物回收利用中的应用

对于碳填充类样品,不管是手持式的还是实验室的近红外技术类仪器都不太可能得到有用的光谱对于不同类型的样品,推荐使用带有ATR的仪器并且配置不同类型的晶体疏松材料测试完成后,基于晶体上残留物的红外光谱,通过配置有ATR的中红外仪器也能够鉴定出一系列的添加剂材料。

PDF 1 MB
使用FT-IR分析再回收利用聚乙烯树脂中的聚丙烯污染物

PerkinElmer公司的Spectrum Two配备单次反射ATR附件能够在数秒内收集到高质量的谱图,而且归功于先进的设计和内置的算法,不需要进行样品前处理,非常方便操作使用。

PDF 1 MB
使用Spectrum Two FT-IR光谱仪分析生物乙醇中的杂质

本报告的研究结果表明,Spectrum Two FT-IR光谱仪可以用于建立定量分析方法,其灵敏度完全可以满足甲醇、水、C3-C5醇和汽油变性剂的检测要求,而且每个样品所需的分析时间不到2min。

PDF 927 KB
使用红外显微镜检测和鉴别化妆品配方中微小的塑料颗粒

幸运8平台彩票微小的塑料颗粒对环境的危害问题越来越受到关注,而且这些微小的塑料颗粒在越来越多的消费产品中被禁止使用。本文证明自动的红外显微镜系统是一种检测和鉴别化妆品中微小的塑料颗粒非常重要的手段。

PDF 1 MB
使用近红外光谱学和化学计量学鉴别真伪磷酸二酯酶抑制剂

幸运8平台彩票该应用文章阐述了如何使用PerkinElmer 带AssureID™和Spectrum 10™软件的Spectrum Two N™ FT-NIR 光谱仪鉴定西地那非、他达拉非和伐地那非片剂的真伪。

PDF 1 MB
建筑玻璃光学和热学性能检测方案

PerkinElmer 公司在建筑材料节能检测行业,能够为建筑玻璃以及建筑涂料的光学参数和热工参数的计算,在硬件和软件上为客户提供一套完整的解决方案,可准确的测试可见光透射比、可见光反射比、太阳光透射比、太阳光反射比、太阳辐射吸收系数、太阳能总透射比、遮阳系数、传热系数、半球辐射率等参数。

PDF 1 MB
推动红外光谱的进步:充分利用润滑油状态现场监测

本文评论了润滑油状态的红外光谱监测,描述了PerkinElmer的“在用润滑油傅里叶变换红外光谱分析系统(In-Service Lubricants FT-IR Analysis System)”这一润滑油现场分析仪的设计考量。

PDF 1009 KB
掺杂物筛查(Adulterant Screen)算法在使用傅里叶变换衰减全反射(ATR)红外光谱法检测橄榄油掺杂物中的优势

本应用报告叙述了一种快速简单筛查橄榄油掺杂物的低成本解决方案。

PDF 2 MB
红外光谱仪用于电子产业链产品用胶水固化率测试

幸运8平台彩票本文利用PerkinElmer Spectrum Two 红外光谱仪测试电子产业链用胶水的固化率,操作简单,无需前处理,不消耗化学试剂,环保安全。测试所需样品量小,基本无样品破坏性,适用于样品无损检测。

PDF 1 MB
红外光谱法测定润滑油的碱值

碱值是内燃机润滑油特别是柴油机润滑油的一项十分重要的指标。本文提出了利用傅里叶变换红外光谱快速测定润滑油碱值的方法。

PDF 367 KB
聚合物回收利用套装

聚合物的回收利用是一个蓬勃发展的行业,许多曾经被作为废弃物填埋的瓶子和容器现在被回收利用为新的产品。由于聚合物存在互不相容的趋势,鉴别聚合物是聚对苯二甲酸乙二醇酯(PET)或聚乙烯(PE)而不是聚碳酸酯(PC)或聚苯乙烯(PS),这样的问题很重要。聚合物的化学鉴别可通过使用Spectrum Two傅里叶变换红外光谱仪与通用全反射(UATR)附件实现。

PDF 1 MB
运用低成本红外光谱仪分析土壤主要功能特性—营养性和污染性

土壤测定对于世界持续的人口膨胀来说至关重要。虽然一些以实验室为基础的技术可用于这些测量,但事实已表明中红外可以进行土壤污染程度和营养水平的分析,且快速和成本低。

PDF 841 KB
高分子材料的中红外光谱鉴别

幸运8平台彩票本应用报告描述了典型高分子样品红外光谱测试和解析的几种方式, 并将其应用于一些工业用高分子材料的识别。

PDF 1 MB
高性能Spectrum Two红外光谱仪快速测定柴油中脂肪酸甲酯

幸运8平台彩票PerkinElmer 公司高性能的Spectrum Two 傅里叶变换红外光谱仪,采用Dynascan 抗振干涉仪、OpticsGuard 专利防潮机制、AVI 标准校正、AVC 大气背景扣除等先进技术,保证光谱仪可以在各种环境条件下采集准确、稳定的光谱数据。尤其是OpticsGuard 技术,使仪器对环境湿度没有要求,使用者无需对干燥剂进行维护和更换,通常可以连续工作5 年以上,特别适合化工企业的实验室使用。

PDF 763 KB

技术说明

Applications and Design of a Micro-ATR Objective

Attenuated total reflectance (ATR) techniques are well established in FT-IR spectroscopy for the direct measurement of solid and liquid samples without sample preparation. The technique requires good contact between the sample and a crystal made from a material which transmits IR radiation and has a high refractive index.

PDF 600 KB
Atmospheric Vapor Compensation on Spectrum Two and Frontier FT-IR Spectrometers

The Atmospheric Vapor Compensation (AVC) function on the Spectrum™ Two and Frontier Series addresses the difficult task of reducing the effects of unwanted atmospheric absorptions in sample spectra.

PDF 290 KB
Obtaining Optimum Reproducibility for FT-IR Measurements in ZnSe Liquid Transmission Cells

Zinc selenide is a very useful material for infrared sampling optics, since it is transparent over most of the mid-infrared range, fairly hard and durable and resistant to water and most chemicals. Consequently it is widely used for attenuated total reflectance (ATR) and liquid transmission cells.

PDF 235 KB

指南

Material Characterization Instrument Guide

Guide describing all UV/Vis spectroscopy, FT-IR spectroscopy, thermal analysis, hyphenation technique solutions for material characterization.

PDF 7 MB

文章

A Comparison of Standard Test Methods for Determining FAME in Diesel by Infrared Spectroscopy

As the importance of sustainable energy production increases, so too does the global commitment to using fuels from renewable biological sources. Biodiesel is one such renewable fuel. Consisting of fatty acids of methyl esters (FAME), it is produced from plant crops by transesterification – a reaction in which natural triglycerides are cleaved and reacted with methanol, producing glycerol and FAME. Rapeseed, soy, sunflower, palm and jatropha are just part of the range of feedstocks used globally in the production of biodiesel.

PDF 2 MB
Harnessing the Power of FT-IR to Guarantee Water Safety

This note explores more environmentally-friendly approaches to the use of IR spectroscopy for detecting and quantifying hydrocarbon contamination.

PDF 3 MB
Identification and Quantification of Microplastics in Wastewater Using Focal Plane Array-Based Reflectance Micro-FT-IR Imaging Article

This article describes methods for identifying and quantifying microplastics within organic-rich wastewater samples.

PDF 3 MB
水体中微小塑料颗粒的污染

幸运8平台彩票这篇文章介绍了水体中的微观粒子污染……

PDF 613 KB

海报

Microplastics and their Alternatives for Intentional Use in Products Environmental Agency Austria Poster

This poster describes analytical application example of FT-IR microspectroscopy for microplastic analysis which are used as exfoliating microbeads in cosmetics and personal care products

PDF 1 MB
The Application of Infrared Microscopy for the Analysis of Microplastics in Water-Borne Environmental Samples Poster

幸运8平台彩票This poster describes the detection and identification of plastics in the micron range in the context of oceans, surface waters, and other environmental compartments with the technique of FTIR combined with the features of microscopy and imaging.

PDF 457 KB

现场应用报告

Analyzing Recycled Polyethylene Resin for Polypropylene Contamination Using FTIR

FAR, Field Application Report, Recycled Polyethylene Resin, Polypropylene Contamination, High-density polyethylene, HDPE, PP, PE, Fourier Transform Infrared Spectroscopy, FT-IR, Spectrum Two, ATR, Spectrum Quant

PDF 494 KB

白皮书

日益令人担忧的水体微塑料

该白皮书介绍了水体中微塑料带来的问题以及……