Frontier MIR/NIR Spectrometer | PerkinElmer

幸运8平台彩票

PerkinElmer
check quantity

FRONTIER MIR/NIR + SP10 STD

Frontier™中近红外一体系统能够让您受益于更快的方法开发,降低仪器使用成本,提高效率。

部件号 L1280034
立即购买

请输入有效的数量

请登录后再添加至收藏夹

购物车为空

项目已成功添加到购物车

详情 信息

Frontier™中近红外一体系统能够让您受益于更快的方法开发,降低仪器使用成本。这套最优化的系统提供单独的中红外和近红外双波段的性能。一键操作自动切换波段,让您能够快速转移到下一个样品的测试,无需任何手动配置,提高了您的效率。

全面的Spectrum软件工作站控制Frontier中近红外一体系统,能够支持科研领域的FT-IR分析和工业实验室,都能提供最佳的结果。革新的Spectrum AssureID™软件让样品的鉴定进入一个新的水平。这种强大直观的用户界面提供生产快速的QA功能,明确的方法去验证成品材料的成分和质量。符合性的选项很容易在监管环境中使用。

Frontier光谱仪固有的灵活性给我们提供除了标准采样附件之外的专业化应用的附件的独特选择性。

规格

21 CFR Part 11兼容 Yes
深度 60.0 cm
Detector Type DTGS
高度 30.0 cm
工作范围(-60to400) 5 - 40 °C
便携式 No
产品品牌名称 Frontier
产品组 Instrument
保修 1 year
波长范围 14,700 – 350 cm-1
重量 34.0 kg
宽度 52.0 cm

配置

Detector Type External Beam Pack? NIRA Included? Software Part Number
DTGS No No Spectrum 10 L1280034
DTGS No No Spectrum 10 ES L1280035
DTGS Yes No Spectrum 10 L1280038
DTGS Yes No Spectrum 10 ES L1280039
DTGS Yes Yes Spectrum 10 L1280042
DTGS Yes Yes Spectrum 10 ES L1280043
MCT No No Spectrum 10 L1280036
MCT No No Spectrum 10 ES L1280037
MCT Yes No Spectrum 10 L1280040
MCT Yes No Spectrum 10 ES L1280041
资源,活动及更多信息
  • 所有

产品手册

PerkinElmer Frontier FT-IR, NIR and FIR Spectroscopy Brochure

幸运8平台彩票Choose the PerkinElmer Frontier™ range of near-, mid- and far-IR Fourier Transform spectrometers for superior spectroscopic performance in demanding applications. Powerful and adaptable, the Frontier meets all your current analysis needs and can be expanded as your research goals evolve. And with automated range switching, mid- near- or far-IR techniques are available at your fingertips. An exceptional signal-to-noise ratio and photometric performance assures optimal spectral performance to ensure best-in-class sensitivity. This configurable platform provides dependable, consistent and trouble-free operation through years of service.

PDF 12 MB
PerkinElmer Frontier and Spectrum Two FT-IR, NIR and FIR Spectroscopy Brochure

幸运8平台彩票Frontier™ is PerkinElmer’s most powerful, adaptable IR solution yet, specially developed to offer superior performance in demanding applications.

PDF 2 MB

产品说明

Biodiesel IR Fatty Acid Methyl Ester (FAME) Analyzer

The production and distribution of alternative fuels is strictly regulatedby both national and international regulatory bodies. PerkinElmer®, via itsEcoAnalytix™ initiative, provides a series of solutions comprised of analyticalinstrumentation, standard operating procedures, training and support to help meet such regulatory requirements.

PDF 1 MB
Rapid, Cost-Effective Oil Condition Monitoring -- Spectrum OilExpress System

Designed specifically to meet the requirements of the Caterpillar® S.O.SSM program, the JOAP program, and the new ASTM® Methods D7412, D7414, D7415, D7418, Spectrum™ OilExpress is the fastest, most cost-effective Oil Condition Monitoring (OCM) solution for busy test laboratories. OilExpress also uses less than half the solvent required by competing systems, dramatically reducing day-to-day operating costs and making laboratories more competitive.

PDF 862 KB
Universal ATR Polarization Accessory for Frontier FT-IR Spectrometers

幸运8平台彩票Attenuated total reflectance (ATR) techniques have been well established in FT-IR spectroscopy for many years. They offer a convenient alternative to thin-film, KBr pellet or diffuse reflectance measurements.

PDF 146 KB

应用文献

A novel method (TG-IR) for the rapid determination of Total Petroleum Hydrocarbons (TPH) in soil

A gas chromatographic analysis of the extract can provide even greater sensitivity and more detailed compositional information, but further increases the time required for the analysis. Thermogravimetric analysis coupled to infrared spectroscopy (TG-IR) can provide detailed information about the amount and nature of the pollution, while requiring no sample preparation at all. This application note illustrates the kind of data that can be obtained with a modern TG-IR system.

PDF 1 MB
Augmenting Standard Methods of Measuring Airborne PM2.5 Using IR Imaging

The use of IR imaging expands the measurement possibilities by giving information about the individual types of materials present in the collected particles. The information from the IR imaging experiment is not only qualitative (i.e. identification of the particulates), but can also be calibrated to give quantitative information on the components present. The IR imaging measurement will take only five minutes, whereas Ion Chromatography requires solvent extraction of the particulates and would take around 20-25 minutes per sample

PDF 1 MB
Biodiesel Concentration Measurements Using Attenuated Total Reflectance (ATR)

幸运8平台彩票Biodiesel fuels are often blended compositions of diesel fuel and esterified soybean oils, rapeseed oils, or other potential vegetable oils as well as fats. The physical and combustion properties of these biofuels have allowed them to achieve similar performance to diesel fuel. However, there are several characteristics that are of concern. These differences, especially the cetane reduction, require that adequate control of the biofuel concentration be implemented.

PDF 1 MB
Biodiesel Concentration Measurements Using OilExpress

The move to include proportions of biodiesel in everyday fuel has created a host of unresolved issues for both engine manufacturers and diesel consumers. Uppermost among these are questions concerning the concentration of the biofuel (Fatty Acid, Methyl Ester – FAME) and its quality. This application note describes how infrared transmission measurements can be used to address the concentration measurements.

PDF 1 MB
Cavity-enhanced Absorption Spectroscopy for Trace Gas Detection with Frontier

幸运8平台彩票Cavity-enhanced absorption spectroscopy (CEAS) has similarities with the better known cavity ringdown technique (CRDS) which measures the signal decay as a laser pulse emerges through one of the mirrors after successive reflections. By measuring the increase in the rate of decay caused by an absorbing species, CRDS can measure ppb concentrations of small molecules. The ringdown technique has typically been applied to small molecules where the wavelength of a NIR laser source can be tuned across very narrow individual lines of the spectra. In contrast this report describes CEAS using a broadband source applied to larger molecules where the spectra are broader.

PDF 1 MB
Characterization of Textile Fibers Using the PerkinElmer Spectrum 100 with Universal ATR Polarization Accessory

The ability to accurately characterize textile fibres is important in many fields, including textile conservation, forensic analysis and industrial production. Conventional methods such as microscopy and spectroscopy can be used to investigate the morphology and chemistry of a sample, but reveal little about its miscrostructure.

PDF 233 KB
Determination of Oil and Grease in Water with a Mid-Infrared Spectrometer

, The PerkinElmer Frontier or Spectrum Two series of FT-IR spectrometers can be utilized successfully for the determination of oil and grease in water samples. The method shows good linearity and precision, with a detection limit below 0.5 mg/L.

PDF 1 MB
Determining the Source Oil of Biodiesel with Infrared Spectroscopy

Infrared spectroscopy is particularly suitable for the identification of materials, even when the differences between the materials are subtle variations in complex mixtures. In this note we demonstrate that biodiesel from several common feedstocks can be distinguished on the basis of absorption bands arising from double bonds in the fatty acid chains.

PDF 176 KB
Diamond ATR and Calibration Transfer for Biodiesel-Blend Analysis by ASTM D7371

幸运8平台彩票Biodiesel is seldom used neat (B100), typically being blended with fossil diesel at ratios from 5% v/v (B5) to 30% v/v (B30). Verifying the FAME content of diesel-fuel blends is an important aspect of quality control and auditing of blending and distribution operations. Because FAME has a strong infrared absorption at 1745 cm-1 due to the ester carbonyl group, infrared spectroscopy is an excellent technique for this analysis, and there are EN and ASTM® standard test methods describing the procedure

PDF 1 MB
Frontier 痕量气体检测的腔增强吸收光谱 Product Note

使用SLED光源与装有InGaAs检测器的Frontier™的腔增强吸收测试可以实现ppm量级的1,3-丁二烯检测灵敏度。使用同一系统对其他烃类物种进行了测试。使用多道SLED可以增加光谱范围,但是无法在较宽的光谱范围内维持所需要的高反射率。

PDF 512 KB
Investigating Phase Transitions with Variable Temperature ATR

Heated ATR is used to follow the thermal changes in chcolatate, which is largely a suspension of sucrose and cocoa solids in a matrix of cocoa butter.

PDF 1 MB
Milk Adulteration with Melamine - Screening, Testing and Real-Time Detection

幸运8平台彩票This work highlights that screening, testing or real-time detection can be utilized to detect melamine-adulterated milk in a supply chain and that by determining where the sampling is taking place, who is carrying out the measurement and whether the testing is to meet regulation, will define which technology to use.

PDF 1 MB
PerkinElmer Frontier FT-MIR/NIR 系统FT-IR 光谱法用于脂肪生产过程质量控制

幸运8平台彩票幸运8平台彩票开发出基于Frontier FT-IR 红外光谱系统的快速FT-IR 质量控制法。本文主要介绍Frontier FT-IR 这一高效环保的质量控制解决方案,帮助棕榈油行业节约成本。

PDF 7 MB
PerkinElmer 纺织品远红外性能的检测和评价系统

幸运8平台彩票本文采用PerkinElmer的Frontier 傅里叶红外光谱仪测试了纺织品的辐射率。

PDF 1 MB
Rapid Authentication of Larch Fiber Dietary Supplement Ingredient by FT-IR Using Diamond Single Bounce uATR Sampling Device

幸运8平台彩票In order to comply with the new Dietary Supplement current Good Manufacturing Practices (cGMP’s), all dietary ingredients must be identified using a valid scientific method. A PerkinElmer MIR/NIR spectrometer equipped with a single-bounce diamond uATR sampling accessory allows for rapid identification of larch fibers of various grades.

PDF 1 MB
使用FT-IR对传统的中药红花油进行快速的质量控制

在这篇文献中,我们将通过可视化的红外光谱图来展示关于红花油质量的重要信息,并且总的分析时间只有几分钟,甚至更少。

PDF 1 MB
使用PerkinElmer Frontier FTMIR/NIR 光谱仪用快速FTIR-ATR 和FT-NIR 光谱法把控皂化生产质量

本文使用 PerkinElmer Frontier FT-MIR/NIR 光谱仪,结合衰减全反射(UATR) 附件,进行样品质量控制。FT-IR-ATR 方法无需对样品预处理,为油脂制皂业提供了一种高效、 环保、 省时和省钱的解决方案。

PDF 7 MB
使用傅里叶变换红外光谱仪作为一种技术验证枫糖浆的真实性

本文利用傅里叶变换红外光谱仪配备Adulterant Screen和SIMCA模型,可以测量枫糖浆的质量并能检测到任何可能存在的掺杂物。

PDF 1 MB
使用傅里叶变换近红外光谱法FT-NIR检测蜂蜜掺假

傅里叶变换近红外光谱法(FT-NIR)提供了一种快速、准确度高的测试方法,可以进行蜂蜜中掺杂物的检测。

PDF 1 MB
使用单一的近红外测量技术对可可粉中掺杂物以及重要参数进行检测

幸运8平台彩票最初用来评估可可豆质量的方法是切和味道测试,但是这是一种主观技术。液相色谱方法也经常用来检测可可粉,但是这种技术耗时长并且非常复杂。近红外光谱是一种非常快速并且简单的技术用来证实可可粉质量。

PDF 2 MB
使用近红外傅里叶变换光谱确定咖啡烘焙度的研究

本文介绍了使用近红外光谱对咖啡豆和咖啡粉的烘焙度进行快速而简单的检测方法。

PDF 3 MB
使用近红外光谱法确定香料掺假等级

幸运8平台彩票通常被掺假的香料包括大蒜粉,黑胡椒和肉桂。傅里叶变换近红外光谱法(FT-NIR)是一种有效并快速的技术,可以鉴别这些香料是否被掺假。

PDF 3 MB
使用近红外和掺杂物筛查功能快速检测酸奶糖中的掺杂物

近红外光谱(NIR)与掺杂物筛查方法(Adulterant Screen)结合是一种检测酸奶糖中三聚氰胺掺杂物的快速简单的方法。 掺杂物筛查的软件能够准确的预测三聚氰胺的浓度水平以及识别出其它潜在的掺杂物。

PDF 1 MB
小麦粉中蛋白质与水分的含量测定

本文展示了傅里叶近红外光谱在农业生产中小麦粉原料的蛋白质和水分测定中的应用。 结果表明,在低于0.5%的误差下用近红外光谱测定这些性质是完全可行的。

PDF 942 KB
热重-红外-气相色谱/质谱(TG-IR-GC/MS)联用技术分析未知水性样

幸运8平台彩票本文通过使用TL-9000型传输管线有效的将热重-红外-气相色谱/质谱分析仪器进行联用,可用于分析复杂样品体系。

PDF 943 KB

技术说明

A Combined Mid-IR/Far-IR Spectrometer for Analytical and Research Applications

By combining a specialized FIR beamsplitter A Combined Mid-IR/Far-IR Spectrometer for Analytical and Research Applications T E C H N I C A L N O T E INFRARED SPECTROSCOPY www.perkinelmer.com with the standard high-performance Mid-IR (MIR) beamsplitter on a single changeover mechanism, with additional FIR detector, a high performance Mid-Far IR system is available on a single optical bench.

PDF 132 KB
Obtaining Optimum Reproducibility for FT-IR Measurements in ZnSe Liquid Transmission Cells

Zinc selenide is a very useful material for infrared sampling optics, since it is transparent over most of the mid-infrared range, fairly hard and durable and resistant to water and most chemicals. Consequently it is widely used for attenuated total reflectance (ATR) and liquid transmission cells.

PDF 235 KB
Oil Express, version 4

幸运8平台彩票The PerkinElmer Spectrum OilExpress oil condition monitoring system provides a complete solution for laboratories conducting high-throughput used oil analysis. The proven performance and reliability of the syringe-pump-based autosampler and Spectrum 100 FT-IR spectrometer ensure quality spectral data.

PDF 1 MB
Reflection Measurements in IR Spectroscopy

Most materials absorb infrared radiation very strongly. As a result samples have to be prepared as thin films or diluted in non-absorbing matrices in order to measure their spectra in transmission. There is no such limitation on measuring spectra by reflection, so that this is a more versatile way to obtain spectroscopic information. However reflection spectra often look quite different from transmission spectra of the same material. Here we look at the nature of reflection spectra and see when they are likely to provide useful information. This discussion considers only methods for obtaining so-called external reflection spectra not ATR techniques.

PDF 1 MB