PerkinElmer

热重分析 (TGA)

OF

对于热重分析中的高产量和可靠性,没有人比PerkinElmer更好地控制样品环境。自1960年以来,我们一直是TGA的先驱,为表征各种复杂材料提供最强大的仪器。其应用包括:

  • 环境
  • 食品
  • 制药
  • 石化

产品与服务 (3)
Filters:

幸运8平台彩票1-3 的 3 产品与服务

幸运8平台彩票

  • TGA 4000 N5370210

    TGA 4000 系统, 100-240V/50-60Hz

    TGA 4000 炉体采用集约式陶瓷设计,温度控制准确度和精度更高。其陶瓷炉体耐化学腐蚀性优异,适用于多种活性气体气氛,可充分拓展您的研究领域。
  • TGA 8000 Thermogravimetric Analyzer

    TGA 8000 Thermogravimetric Analyzer

    Our TGA 8000 thermogravimetric analyzer gives you complete control over your sample environment and delivers high throughput and reliability, even unattended. Plus, advanced hyphenation technology works beautifully with FT-IR, MS, GC/MS, and other systems for better understanding of evolved gases. In other words, this is complex characterization made simple.
  • TGA 8000

    PerkinElmer公司全新推出的TGA8000™型热重分析仪不仅可以让您完全掌控样品的测试环境,而且兼顾了测试所需的高通量和数据可靠性,甚至在无人值守的状态下依然可以完美的高效运行。另外,PerkinElmer公司先进的联用技术赋予这款仪器完美的与FTIR,MS,GC/MS进行联合使用,让您能够透彻的研究逸出气体的定性定量信息。
Business Insights (4)
Filters:

1-4 的 4 Business Insights

  • 应用文献

    Soot Content Determination of In-Service Lubricants of Diesel Engine as Per ASTM D5967 Annex A4

    幸运8平台彩票Internal combustion in an engine produces soot as a result of incomplete fuel combustion. The soot deposits deplete the quantity of dispersant additives which may cause an increase in viscosity which in turn increases engine wear. These soot particles adversely affect the engine performance and can lead to damage of the engine parts. This application note demonstrates the quantification of soot content as well as the repeatability of the measurement.

  • 应用文献

    A novel method (TG-IR) for the rapid determination of Total Petroleum Hydrocarbons (TPH) in soil

    幸运8平台彩票A gas chromatographic analysis of the extract can provide even greater sensitivity and more detailed compositional information, but further increases the time required for the analysis. Thermogravimetric analysis coupled to infrared spectroscopy (TG-IR) can provide detailed information about the amount and nature of the pollution, while requiring no sample preparation at all. This application note illustrates the kind of data that can be obtained with a modern TG-IR system.

  • 应用文献

    Analysis of Polluted Soil by TG-IR Technique

    One of the most challenging analytical problems with increasing importance is the possibility to analyze soil polluted by the dispersion of organic fluids which sometimes features particularly high boiling points. The current techniques used solvent extraction and headspace chromatographic analysis, have shown their limits. Solvent extraction needs time consuming sample preparation. Headspace makes it impossible to heat the sample at temperatures exceeding 200 °C, which risks not being able to identify the heaviest fractions of the polluting agents.

  • 案例分析

    Renault F1® Team - Stronger and Safer with PerkinElmer Analysis

    PerkinElmer has been helping Renault F1 Team's Enstone Technical Center with their analytical needs for nearly 30 years. PerkinElmer began by outfitting the team’s testing lab with the analytical instrumentation needed to conduct materials testing. Today, a dedicated PerkinElmer scientific laboratory operates within the team’s Enstone facility where the latest thermal analysis, infrared spectroscopy, and imaging technologies are being utilized for proactive monitoring, issue prevention, and performance enhancement of the team’s single seater. This case study shows you how we offer analytical expertise in helping Renault F1 Team master the thermal stability challenge.